MIL-STD-849B
TABLE XV. Classification of defects - solid and extended skirt parachute canopies - cargo.
Classification
No. Defect Major/Critical Minor
1. |
Improper assembly of vent reinforcement band |
101 |
|
2. |
Vent reinforcement band overlap Up to 1/2 inch minus Over l/2 inch minus Over 1 inch plus |
102 |
201 202 |
3. |
Vent hem outside stitching margin from edge of webbing 1/16 to 1/4 inch Over 1/4 inch |
103 |
203 |
All rows of stitching not through reinforcement webbing |
104 |
||
4. |
Vent loop length (finished dimension) Up to 3/4 inch shorter Over 3/4 inch shorter |
105 |
204 |
Over 1/2 inch longer |
106 |
||
5. |
Vent line length (finished dimension) Up to 3/8 inch Over 3/8 inch |
107 |
205 |
6. |
Variation in vent line length per set Up to 1 percent Over 1 percent |
108 |
206 |
7. |
Twisted vent line (flat) Up to 180 degrees Over 180 degrees |
109 |
207 |
8. |
Twisted vent line (core or coreless braid) Over 360 degrees, causing kinks in line when relaxed |
110 |
|
9. |
Gore width at vent, centerline to centerline on main seam Up to 1/4 inch Over 1/4 inch |
111 |
208 |
10. |
Gore width at skirt, centerline to centerline on main seam Up to 1/2 inch Over 1/2 inch |
112 |
209 |
11. |
Improper type of or improper assembly of cross and main seams |
113 |
65
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business