MIL-STD-849B
TABLE IV. Classification of defects - ring slot and ribbon parachute canopies.
Classification No. Defect Major/Critical Minor
1. |
Improper assembly of vent reinforcement band |
101 |
|
2. |
Vent reinforcement band overlap Up to 1/4 inch minus Over 1/4 inch minus Over 1/2 inch plus |
102 |
201 202 |
3. |
Vent loop length (finished dimension) Up to 1/2 inch Over 1/2 inch |
103 |
203 |
4. |
Vent line length (finished dimension) Up to 1/4 inch Over 1/4 inch |
104 |
204 |
5. |
Variation in vent line length per set Up to 1 percent Over 1 percent |
105 |
205 |
6. |
Twisted vent line (flat) |
106 |
|
7. |
Twisted vent line core or coreless braid Over 360 degrees Over 360 degrees causing kinks in line when relaxed |
107 |
206 |
8. |
Gore width at vent, measured centerline to centerline on adjacent radial seams Up to 1/4 inch |
207 |
|
Over 1/4 inch |
108 |
||
9. |
More or less than the required number of ribbons per gore |
109 |
|
10. |
Spacing of horizontal ribbons (ribbon canopy) Up to 3/16inch Over 3/16 inch |
110 |
208 |
11. |
Spacing of verticals Up to 1/4 inch Over 1/4 inch |
111 |
209 |
30