MIL-STD-849B
TABLE XI. Classification of defects - canopies: square, gliding type - main and reserve - Continued.
Classification No. Defect Major/Critical Minor
9. Twisted suspension line between canopy and connector
Over 180 degrees to 360 degrees 205
Over 360 degrees 116
10. |
Twisted control line between canopy trailing edge and upper cascade Over 180 degrees to 360 degrees |
206 |
|
Over 360 degrees |
117 |
||
11. |
Twisted control line between upper and lower cascade over 90 degrees |
118 |
|
12. |
Twisted control line, between lower cascade and loop (per TDP) Over 180 degrees to 360 degrees Over 360 degrees |
119 |
207 |
13. |
Reinforcement tape on ribs Take-up more than 1/4 inch |
120 |
|
14. |
Reinforcement tape and suspension line tape, rib panel connection Missing |
121 |
|
Improperly attached |
122 |
NOTE: The cross box stitch used to secure the
reinforcement tape within the seam shall not cross the primary row of double needle seam stitching. The primary row of stitching shall be understood as the immediate stressed row when load is placed upon the seam.
15. Heat sear of cross port vent holes improperly formed
1 per rib 208
More than 6 per canopy 123
16. Splicing
On canopy fabric 124
Webbing or tape 209
17. Stitching
Bartack stitching not as specified in applicable drawing 125
301 and 308 stitching not in accordance with ASTM D 6193
More than 1 stitch per inch over or under the number specified
55
For Parts Inquires call Parts Hangar, Inc (727) 493-0744