MIL-STD-849B
TABLE XII. Classification of defects - pilot chutes for MC-4 and MIRPS
and spring assembly, ejector only.
Classification No. Defect Major/Critical Minor
1. Assembly of grommets
Improperly set, 2 or more exposed teeth (except where grommet is set as specified but is in an area of unequal
thickness that prevents uniform clinching) 101
Clinched loosely, allowing grommet to rotate in hole 102
Clinched excessively tight, cutting fabric 103
Insecurely clinched, where grommet or washer may
become disengaged 104
Roll of grommet contains splits, burrs or sharp edges 105
2. Seams not constructed as specified in applicable drawing
1 seam 201
2 seams 106
Raw edge exposed 107
Open seam 108
NOTE: Seams will be classified as open when one or more stitches joining a seam are broken or when two or more stitches occur. Conditions repaired by either restitching or overstitching as specified will not be scored as a defect.
3. |
Pleats exceeding 3/16 inch wide |
109 |
4. |
Stitching Bartack stitching not as specified in applicable drawing 301 and 308 stitching in accordance with ASTM D 6193 |
110 |
More than 1 stitch per inch over or under the number
specified
Up to 2 inches |
202 |
|
Over 2 inches |
111 |
|
Broken or missing stitches |
112 |
|
2 or more consecutive skipped stitches |
113 |
|
Missing or incomplete stitch pattern (for example, bartack |
||
or cross box) |
114 |
|
Backstitch missing |
115 |
|
Backstitch short |
||
Less than 1/4 inch |
203 |
|
More than 1/4 inch |
116 |
58
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.