MIL-STD-849B
TABLE IV. Classification of defects - ring slot and ribbon parachute canopies - Continued.
Classification No. Defect Major/Critical Minor
12. Slot width (ring slot canopy)
Up to 1/8 inch 210
Over 1/8 inch 112
13. |
Leading and trailing edge of section hems (ring slot canopies only) |
||
Underfolds where gore fabric is not butted flush with fold of |
|||
hem and caught with 2 rows of stitches (when specified |
|||
by drawing) |
113 |
||
Intermittent underfolds up to 2 inches along seam length |
211 |
||
Underfold over 2 inches along seam length |
114 |
||
Fullness between lines of stitching |
|||
Up to 1/8 inch |
212 |
||
Over 1/8 inch |
115 |
14. |
Gore width at skirt, measured centerline to centerline on adjacent |
||
radial seams |
|||
Up to 1/4 inch |
213 |
||
Over 1/4 inch |
116 |
15. |
Skirt reinforcement band overlap |
||
Up to 1/4 inch minus |
214 |
||
Over 1/4 inch minus |
117 |
||
16. |
Over 1/2 inch plus Improper assembly of skirt reinforcement band |
118 |
215 |
17. |
Underfold (raw edge) skirt hem |
119 |
NOTE: When raw edge is the result of overfolding, the
edge extending more than 1/2 inch but less than 1 inch, the raw edge may be trimmed and will not be scored as a defect. If the condition extends more than 1 inch from the inside edge of the skirt hem, the stitching will be removed and the hem refolded and restitched.
18. |
Pleats (all hems) |
||
1/8 to 1/4 inch and 1 per gore |
216 |
||
Over 1/8 inch and over 1 per gore |
120 |
||
Over 1/8 inch and over 6 per canopy |
121 |
||
Over 1/4 inch |
122 |