MIL-STD-849B
TABLE III. Classification of defects - solid and extended skirt parachute canopies - personnel.
Classification No. Defect Major/Critical Minor
1. |
Improper assembly of vent reinforcement band |
101 |
|
2. |
Vent reinforcement band overlap Up to 1/4 inch minus Over l/4 inch minus Over 1 inch plus |
102 |
201 202 |
3. |
Vent hem outside stitching margin from edge of webbing 1/16 to 3/16 inch Over 3/16 inch |
103 |
203 |
All rows of stitching not through reinforcement webbing |
104 |
||
4. |
Vent loop length (finished dimension) Up to 1/2 inch plus Over 1/2 inch plus |
105 |
204 |
Minus direction any length |
106 |
||
5. |
Vent line length (finished dimension) Up to 1/4 inch Over 1/4 inch |
107 |
205 |
6. |
Variation in vent line length per set Up to 1 percent Over 1 percent |
108 |
206 |
7. |
Twisted vent line (flat) |
109 |
|
8. |
Twisted vent line (core or coreless braid) Over 360 degrees Over 360 degrees, causing kinks in line when relaxed |
110 |
207 |
9. |
Gore width at vent, centerline to centerline on main seam or as stated in TDP Up to 1/4 inch |
208 |
|
Over 1/4 inch |
111 |
||
10. |
Gore width at skirt, centerline to centerline on main seam or as stated in TDP Up to 1/2 inch |
209 |
|
Over 1/2 inch |
112 |
19