MIL-T-43238C
Classification
Minor
Examine
Major
Defect
Hardware (screws,
Two screws or nuts missing
X
nuts,eyebolts,
Three or more screws or nuts missing
x
pins, rivets)
(cont'd)
Electrical system
x
Component missing or not type specified
Loose components (i.e., ballasts, lamp-
x
holder) or loose wiring connections
x
Frayed or broken insulation
Conduits and junction boxes not secured
x
to table body as specified
x
Ground conductor not connected to frame
Electrical data
x
Plate missing
plate and
Not located as specified
x
marking
Marking or wiring diagram incorrect
x
or illegible
Identification
Plate missing or not located as
plate and
x
specified
marking
Marking incorrect or illegible
x
4.4.4 End item dimensional examination. The end item shall be examined for
the dimensional characteristics listed below. Any dimensional chatacteristics
deviating from the specified requirements shall be classified as a defect,
The lot size shall be expressed in units of tables. The sample unit shall be
one table. The inspection level shall be S-2 and the AQL, expressed in terms
of defects per hundred units, shall be 4.0.
Overall frame dimensions
Location of ballasts
Location of lampholders
Positioning of leg assemblies
Positioning of locking arrangement components
4.4.6 Packing inspection. An examination shall be made to determine that
the preservation, packing, and marking comply with section 5 requirements.
Defects shall be scored in accordance with the list below. The sample unit
shall be one shipping container fully packaged. The lot size shall not be the
6