MIL-DTL-44033B
4.4 Examination. Each concentric line assembly shall be
examined for compliance with the requirements specified in 3.2
though 3.5. This element of inspection shall encompass all
visual examinations (see 4.5) and dimensional measurements (see
4.6). Noncompliance with any specified requirements or presence
of one or more defects preventing or lessening maximum efficiency
shall constitute cause for rejection of the lot.
4.5 End item visual examination. The end items shall be
examined for the defects listed in Table I. Noncompliance with
any specified requirement shall constitute a defect.
TABLE I. End item visual examination
Classification
Defect
Examine
minor
major
101
Not specified type or class
Webbing
201
Color not as specified
Ends not wax dipped or
202
seamed as specified
Hole, tear, or cut in material 102
Abrasion resulting in rupture
of yarns, or in nap sufficient
to obscure the identity of any
yarns exceeding 10 percent of
103
width or 1 inch in length
Edge frayed, beaded, corded,
104
or torn
203
Two broken warp or fill yarns
More than two broken warp or
105
fill yarns
204
1/2 inch or less
Open Seams
106
More than 1/2 inch
Note: A seam shall be classified as open when one or
more stitches joining a seam are broken or when two or
more consecutive skipped or runoff stitches occur.
(See Open Seams)
Run-off
107
Wrong stitch type
Stitch type
5